Wednesday, February 3, 2010
Today we did a protein quantitation using BioRad's Quick Start™ Bradford Protein Assay, a method in which a dye reagent is used (Bradford reagent, based on Brilliant Blue G-250) to bind to proteins (causing the dye reagent to change to a different color) and measure its absorbance. The more concentrated the protein it binds, the darker the blue resultant color, and the greater the absorbance at 595 nm.
Two relative standard proteins are used, bovine serum albumin (BSA)and bovine gamma-globulin (BGG), to generate absorbance vs. protein concentration curves and then interpolate the absorbance of problem samples to estimate their concentration. The protein samples obtained from the Hydrophobic Interaction Chromatography (HIC) are used as problem samples.
This method is applied when researchers in proteomics discover a new protein and are trying to gather information about it. In our case, we "discovered" GFP, although we wouldn't have a name yet, had it been a truly newly discovered protein.
----------------------